GE Healthcare · X-ray VascularInnova50125
The TSSC has an error code flashing in the Mag Mode and Auto Positioner.
Symptom
The TSSC has an error code flashing in the Mag Mode and Auto Positioner. Customer thought that FOV of detector was changing The TSSC has an error code flashing in the Mag Mode and Auto Positioner. The customer may think the FOV on TSSC was changing values by itself, while the FOV is displaying error code
Error message
50125 POS : TSUI: SMB OR SMH ERROR 4ACA HW 00A5 User 0000 (SH master - Permanent enable: GANTRY MOTION ENABLE (c-arc & pivot)) TSUI: SMB OR SMH ERROR DO POS 0 0 HWStatus=00CA User=0000 0001 4ACA SH slave - Joystick motion: GANTRY MOTION (c-arc & pivot) 0x0010 Master TSSC - coherence box problem 0x0011 Master TSSC - satellite missing: Collimator joystick – II1 0x0012 Master TSSC - satellite missing: Contour filters joystick – II3 0x0013 Master TSSC - satellite missing: Autopos joystick – II4 0x0014 Master TSSC - keyboard missing 0x0015 Master TSSC - permanent enable: Autopos – II4b1a 0x0016 Master TSSC - Permanent enable: Lateral tube control – II9b 0x0017 Master TSSC - Permanent enable: Service mode (X101 /102) - II11b 0x0018 Master TSSC - Permanent enable: Fast spin test button – II13 0x0019 Master TSSC - Joystick motion: Autopos – II4 0x0020 Master TSSC - Button stuck: COLLIMATOR CONTROL JOYSTICK 0x0021 Master TSSC - Button stuck: COLLIMATOR AUTO-FORMAT 0x0022 Master TSSC - Button stuck: IRIS CLOSING 0x0023 Master TSSC - Button stuck: IRIS OPENING 0x0024 Master TSSC - Button stuck: CONTOUR FILTER CONTROL JOYSTICK 0x0025 Master TSSC - Button stuck: CONTOUR FILTER AUTO-FORMAT 0x002
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.