GE Healthcare · X-ray VascularInnova10500951050002
All Gantry axis's will not drive
Symptom
INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor
Error message
1050095 Pivot AXIS CONTROL LOOP Failsafe error 1050095 DO Pivot AXIS CONTROL LOOP GantryAxis:null Pivot_AXIS_CONTROL_LOOP Failsafe ERROR 1050095 DO Pivot AXIS CONTROL LOOP GantryAxis null Pivot_AXIS_CONTROL_LOOP Failsafe ERROR Pivot: axis control loop problem: A problem has been detected by the Pivot MCB board in its control Loop 1050002 DO GantryAxis BUDDY Larm AXIS ENABLE disable from buddy 1050002 DO BUDDY Larm AXIS ENABLE GantryAxis null BUDDY_Larm_AXIS_ENABLE disableFromBuddyN This error is caused by the Buddy of the LARM (Pivot MCB) disabling the enable of the LARM, to prevent Gantry motion during a failure. The disable is issued when the Buddy AMP detects a failure on the LARM or the Buddy (Pivot) has failed 1050002 DO BUDDY Larm AXIS ENABLE GantryAxis null BUDDY_Larm_AXIS_ENABLE disableFromBuddyN This error is caused by the Buddy of the LARM (Pivot MCB) disabling the enable of the LARM, to prevent Gantry motion during a failure. The disable is issued when the Buddy AMP detects a failure on the LARM or the Buddy (Pivot) has failed.
Applies to
- Models
- Innova
- Product
- X Innova 2100 Do not use Innova 2100iq System Innova 2100
- Software
- Unity 3D M4 SP2 Unity 3D M4 SP2 Fwd Prod. DL Release : DL_UNITY_4.17.5 Ghost DL : 21.22.1 DL : DL_Unity_4.17.5 DL Atlas Core : 4.2-8_5 RTAC Atlas Core : 4.2-8_5 IDC : 5.26 Calypso : 4.37 Calypso Uptime : CLYUPT.UNITY_4.15 Positioner : RR POS LBY 1.4.4U_13 Jedi : P636RC1
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.