GE Healthcare · X-ray VascularInnova105023310502591050278
The Omega table elevation will not drive down vertically.
Symptom
The Omega table elevation will not drive down vertically. When the customer selects the down elevator motion, the enable works, but the table does not lower. The elevator up function is normal. The Omega table top will not drive down vertically. When the customer selects the down elevator motion, the enable works, but the table does not lower. The elevator up function is normal.
Error message
1050233 POS BOOT / Debug - One MCB extended PRD failed 1050259 Stepper Board Initialization Error 1050259 STEPPER INIT BOARD ERROR WR GantryAxis 0 STEPPER_INIT_BOARD_FAILURE 1 0 - -- OMEGA4/5 -- motorization licensed asked by System, BUT stepper not available Z:/heroic/table_geometry_task.c 480 1050259 STEPPER INIT BOARD ERROR WR GantryAxis 0 STEPPER_INIT_BOARD_FAILURE 1 0 - -- OMEGA4/5 -- motorization licensed asked by System, BUT stepper not available Z:/heroic/table_geometry_task.c 1050278 CPU Stepper Board Serial Communication Failure 1050278 CPU STEPPER BOARD SERIAL COM DO GantryAxis Reset From Back Plane Component(s)_Positioner_CPU_Table_Serial_communication 1 0 - Stepping board PRD no response Z:/heroic/table_geometry_task.c 1168
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Omega IV Cardiac table Omega IV Cardiac table Omega IV cardiac table Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.