GE Healthcare · MRExcite225229452239
Running diagnostics on the Driver Module failed indicating that the Multi-Coil Board #1 was not present. 11x to 14x upgr…
Running diagnostics on the Driver Module failed indicating that the Multi-Coil Board #1 was not present. 11x to 14x upgrade.
Symptom
Unable to use the A port when scanning with the HD TRknee PA coil 11.0 to 14.0 upgrade See long description System upgrade where everything worked fine accept coils plugged into the A port. In this case, they only had the one coil, but could not get it to scan. System reporting that the Driver Module was detecting an invalid Configuration. Source of Fault is Multi-Coil Board #1 not present.
Error message
2252294 The Driver Module Has Detected an Invalid Configuration. Source of Fault is Multi-Coil Board #1 Not Present.-> Dec 20 Thu 18:40:55 2252294 NSP SCP:DCB 304 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: HD TRknee PA Scan: 52239/1 The Driver Module Has Detected an Invalid Configuration. Source of Fault is Multi-Coil Board #1 Not Present.-> See Long Description for Extended log... Error Code as viewed through the Service Browser with the Service Key installed: Dec 20 Thu 18:40:55 2252294 NSP SCP:DCB 304 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: HD TRknee PA Scan: 52239/1 The Driver Module Has Detected an Invalid Configuration. Source of Fault is Multi-Coil Board #1 Not Present.-> Extemded Log viewed by clicking on the Hyperlinked Error code above: 2252294 ERROR: EM_DCB_CONFIG_FAIL The Driver Module Has Detected an Invalid Configuration. Source of Fault is %b. Extended Error: The requested Driver configuration has been determined to be invalid. The source of the fault will give specific information regarding the fault. Fault could be caused by hardware or software. Possible cause(s): Driver Modul
Applies to
- Models
- Excite
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Component
- 5141870-2 Cable Run 1203 HDx Systems
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.