Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.

Symptom

Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76

Error message

600104 Collimator Control error Acquisition aborted; Collimator CAN communication failure 600104 Collimator Control error Acquisition aborted; re-start AR XRBeamForm control Component(s)_Collimator 1 63 Collimator CAN communication failure XRBeamForm.cpp 2068

error Code = 1000014, error Text = SID_SSD out of range, debug Text = SID out of range, recovery Class = IH, major Function /= XRImChainPos System impact: X-ray unavailable. Displayed message : "SID pb, use lift orange button to move detector to highest position". Note: This error is also logged when the positioner is resetted.

50127 POS : Call Service; gantry failure 50127 WR POS POS : Call Service; gantry failure Debug: fct-status=0 hw-status=0 pos-error=4acc usr-status=0 HWStatus=0000 User=0000 0000 4ACC Root Cause:Positioner CPU-CSB Communication. This error is due to timeout or error found on Positioner CPU to the Capacitive Sensor Board communication. So it could be CPU, Backplane or Capacitive Sensor Board. 50127 WR POS POS : Call Service; gantry failure Debug: fct-status=0 hw-status=0 pos-error=4acc usr-status=0 HWStatus=0000 User=0000 0000 4ACC Root Cause: Positioner CPU-CSB Communication. This error is due to timeo

Applies to

Models
Innova
Product
Innova 2000 Innova 2000 systems Innova 2000 systems Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Component
Innova Collimator Innova collimator Innova collimator Positioner Gantry Positioner Gantry Positioner Gantry
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues