Can't Display Images Written to CDR or DVD on Excite HD using Centricity DICOM Viewer version 2.1 on a PC or Laptop
Symptom
Can't Display Images Written to CDR or DVD on Excite HD using Centricity DICOM Viewer version 2.1 on a PC or Laptop See Long Description MR customers in Japan are trying to use the Centricity viewer version 2.1 on their PCs/laptops which are loaded with the Japanese version of Windows XP to read CDRs/DVDs written on the Excite HD system and cannot view the thumbnails nor the images. These PCs/laptops are running Internet Explorer 6.0 with Windows XP SP2 package: ver6.00.2900.2180. (Version of IE is 6.0.2900.2180.xpsp_SP2_gdr.050301-1519). This was demonstrated on several PCs/laptops running this version of IE. The same CDRs/DVDs are successfully read on SP1 version. (ver6.00.2800.1106). However, it doesn't appear to be version-related as other PCs running this same version of IE were demonstrated to not have this problem. Upon inserting the CDR or DVD in the PC's CD/DVD drive, the Centricity DICOM viewer version 2.1 automatically starts with Internet Explorer, and a dialogue is displayed that says "Centricity DICOM Viewer has been tested with Internet Explorer 5.5 Service Pack2 and Internet Explorer 6.0 . Centricity DICOM Viewer is not guaranteed to work with the currently installed version." After that, no image is shown on viewer screen and no list is shown. Just wallpaper and menu of IE 6.0 is displayed. SPR MRIhc12966
Error message
Centricity DICOM Viewer has been tested with Internet Explorer 5.5 Service Pack2 and Internet Explorer 6.0. Centricity DICOM Viewer is not guaranteed to work with the currently installed version See Long Description Upon inserting a CDR/DVD with images "burned" on an Excite HD system into a PC with the Centricity DICOM Viewer software loaded, this message appears: "Centricity DICOM Viewer has been tested with Internet Explorer 5.5 Service Pack2 and Internet Explorer 6.0 . Centricity DICOM Viewer is not guaranteed to work with the currently installed version."
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.