Cannot scan with multiple Receiver and RRF Errors Due to Receiver.
Symptom
Cannot scan with multiple Receiver and RRF Errors See long description Error: 2248237 APS:RrfCalibrator::getOffsetsCleanu Line: 1423 The present state of the system resulted in a failure to blank(0) or unblank(1) (Request = 1) receiver -1. APS:RrfCalibrator::getOffsetsCleanu Line: 1423 The present state of the system resulted in a failure to blank(0) or unblank(1) (Request = 1) receiver -1 ADITIONAL ERRORS: Error: 2248238 Host: DCH Process: NSP File: APS:RrfCalibrator::getOffsetsCleanu Line: 1446 Channel=3, Written Value = 0, Returned Value = 1 If this occurs often you may have RRF chassis communication problem Error: 2247154 Host: DCH Process: diagCoord File: Receiver.cpp Line: 349 Task ID: 0xf8bb38 Time: 14756 Object: APS The IRF driver function Receiver::rx set unblank failed to write a new control value to the RRF. Channel=3, Written Value = 1, Returned Value = 0 If this occurs often you may have RRF chassis communication problem.-
Error message
2247154 The IRF driver function Receiver rx_set_r1_atten failed to write a new control value to the RRF. Task ID: 0x7effdf0 Time: 1352 Object: APS Exception Class: Unknown Function: RF: RF Transmit The IRF driver function Receiver::rx_set_r1_atten failed to write a new control value to the RRF. Channel=4, Written Value = 0, Returned Value = -12 If this occurs often you may have RRF chassis communication problem.-> 2247154 Task ID: 0x7effdf0 Time: 1352 Object: APS Exception Class: Unknown Function: RF: RF Transmit The IRF driver function Receiver::rx_set_r1_atten failed to write a new control value to the RRF. Channel=4, Written Value = 0, Returned Value = -12. If this occurs often you may have RRF chassis communication problem.-> 2248238 If this occurs often you may have RRF chassis communication problem Error: 2248238 Host: DCH Process: NSP File: APS:RrfCalibrator::getOffsetsCleanu Line: 1446 Channel=3, Written Value = 0, Returned Value = 1 If this occurs often you may have RRF chassis communication problem. 2248237 The present state of the system resulted in a failure to blank or unblank Error: 2248237 APS:RrfCalibrator::getOffsetsCleanu Line: 1423 The present state of the syst
Applies to
- Models
- Excite
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Component
- 2349808-2 NMR Receiver II EMC ED2 Compliant 2349808-2 NMR Receiver II EMC ED2 Compliant
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.