GE Healthcare · X-ray VascularInnova28000065000020
After replacing a RTAC Gitane board with a DL Gitane board the RTAC would not boot.
Symptom
After replacing a RTAC Gitane board with a DL Gitane board the RTAC would not boot. The DL could not communicate with the RTAC or Reset system; if problem persists, call Service After replacing a defective RTAC Gitane board with a DL Gitane board the RTAC would not boot. The DL could not communicate with the RTAC or Reset system; if problem persists, call Service
Error message
2800006 System comms error detected by subsysmgr DL 2800006 System comms error detected by subsysmgr AR XRSubSysMgrDL control Component(s)_ETHERNET_Communication 1 0 (null) XRSubsysMgrDLImpl.cxx 668 5000020 Error in Communication Infrastructure DO SubSysMgr control Component(s)_ETHERNET_Communication 1 0 XRUserIfDL::COMM_ERROR_7 :: ERROR: PublishEvent on Other Router GenericActor.cpp 1759 5000020 Error in Communication Infrastructure DO SubSysMgr control Component(s)_ETHERNET_Communication 1 0 XRUserIfDL::COMM_ERROR_7 :: ERROR: PublishEvent on Other Router GenericActor.cpp 1759
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- Innova 4100 M4+ (FMI 12013) DL3 Ghost 18.5 ; DL5 Ghost 20.1 DL Applications version 3040.20.6 Jedi L630 Ghost DL-5 : 20.1 Ghost DL-3 : 18.5 DL : 3040.20.6 DL Atlas Core : 3.1Q RTAC Atlas Core : 3.1Q IDC : 2.8.2 Calypso : 1.13 Calypso Uptime : 3.3.2 Positioner : 1.2.24 Jedi : L630
- Component
- RTAC in Innova RTAC in Innova RTAC in Innova
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.