GE Healthcare · X-ray VascularAdvantxInnova30050
No Acquisition exposure, fluoro or record
Symptom
No Acquisition exposure, fluoro or record will not fluoro or record after boot. No issue with Positioner movement, DL, Rtac and detector is up. Innova 2100iq system will not fluoro or record after boot. No issue with Positioner movement, DL, Rtac and detector is up. Error 3200011
Error message
Advantx 42BE: :Power unit inverter 1 failure. Call service. followed by 4260 Error 42BE :Power unit inverter 1 failure. Call service In–Room Display Message: POWER UNIT ERROR. CALL SERVICE. HW code: N/A User Code: N/A This Error is usually followed by Error 4260: Power Unit in a reset state due to Error. The system will not allow exposures. This error indicates that the system has detected an error on inverter 1 30050, error Text = POWER UNIT : THYRISTOR TQ FAILURE, debug Text = HWStatus=0036 User=0000 0000 42E6, recovery Class = DO, major Function /= ECM System impact: None. 1 tube spit that can be heard by customer. Displayed message : None. ADTX error 42E6. Vamp errror 30050 DO ECM POWER UNIT : THYRISTOR TQ FAILURE Debug: fct-status=0 hw-status=36 pos-error=42e6 usr-status=0 HWStatus=0036 User=0000 0000 42E6 Vamp errror 30050 DO ECM POWER UNIT : THYRISTOR TQ FAILURE Debug: fct-status=0 hw-status=36 pos-error=42e6 usr-status=0 HWStatus=0036 User=0000 0000 42E6
Applies to
- Models
- Advantx, Innova
- Product
- Advantx E Biplane Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Advantx E biplane systems: LCLP+ (22 cm II), LCN+ (32 cm II), LCALP+ (40 cm frontal plane, 32 cm lateral plane) Innova 2000 Innova 2000 systems Innova 2000 systems Advantx, LFX Advantx product line LFX Advantx product line Advantx E Monoplane Advantx E Systems advantx e, vamp Advantx E generator Systems
- Component
- Vamp inverter power supply fuses Vamp inverter power supply fuses part # CG10A1024H02 (200 amp). 45441291200 AMP FUSE KIT (FOR DC BUS) Vamp inverter power supply fuses part # CG10A1024H02 (200 amp), 45441291200 AMP FUSE KIT (FOR DC BUS)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.