Geometry errors Due To Software Update ServicePack-02.
Symptom
Intermittent ROTMI Calculation Errors Seen at Download See Long Description SMILe March 5, 2007 This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Subject: Intermittent ROTMI Calculation Errors Seen at Download And Recommended Customer Workaround. Effectivity: All Signa 1.5T and 3.0T MR Systems operating with 11.0M4 SP1, 12.0M5 SP2, 14.0M4 SP1, and 14.0 SP2. Problem: Sites have reported intermittent ROTMI calculation errors at download time for specific pulse sequences. The following error message is logged in the gesys log: "Rotmi Calculation Error found during Download". This error text corresponds to error codes 2218692 (14.0 platform), 2218717 (12.0 platform), and 2218674 (11.0 platform). This issue primarily occurs on Radial and MSMA prescriptions. In 2006 a potential safety issue was reported and, to prevent scanning after a geometric calculation error, a download failure that resulted in an error message stating, "Rotmi Calculation Error found during Download" was introduced. Unfortunately, this fix used too broad of a detection for radial prescriptions. Resolution: When a ROTMI error occurs the workaround is to force a recalculation using very slightly different locations that cover the same anatomy. Do not simply reuse the failing graphic prescription. Ask the customer to perform these steps: View-Edit the current Series which has the download failure. On the GRx window, select the slices. Click [Erase Selected]. Re-prescribe the graphic prescription. Do not use Copy-Rx. Do not copy/paste the GRx prescription. Do not use Copy-Series or Paste-GRx from the series which had the download failure. A new version of the preventive fix, which more precisely detects an error, is in validation at this time and will be released as soon as possible. Field Engineers and Apps Specialists : Notify the site and advise of the above workaround. Verify that the workaround is being implemented correctly. If the workaround is unsatisfactory, please enter a product complaint (PQR/iTrak) and, if necessary, contact OnLine Center support. Jacqui Budde Software Engineering GE CONFIDENTIAL! © 2007 General Electric Company CLASS M DOCUMENTATION--PROPERTY OF GENERAL ELECTRIC COMPANY FOR USE BY GE PERSONNEL ONLY ANY OTHER USE EXPRESSLY PROHIBITED
Error message
2218681 Rotmi Calculation Error found during Download Fri Jan 19 10:56:01 2007 Error: 2218681 Host: MR1 Process: scn File: RxManagerIF.m Line: 868 Rotmi Calculation Error found during Download
Applies to
- Models
- Excite, Signa
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.