GE Healthcare · X-ray VascularInnova15131104152008052965660
QAP or IQST fails image Quality Testing
Symptom
QAP or IQST fails image Quality Testing QAP or IQST fails image Quality Testing. During QAP testing the system may report Quality Assurance Program could not be done. Internal Error. Please run the application again or call GE Service. The system fails to complete Quality Assurrance testing
Error message
QAP / IQST log indicates one or serveral Bad Pixel tests fail QAP / IQST log indicates one or serveral Bad Pixel tests fail. The results.html file indicates a "failed" status for several of the bad pixel tests. script redux element("Global Bad Pixel Counts 20cmFOV", " 450", "0", "10", "fail" , "above USL") /script script redux element("Global Bad Pixel Counts Max FOV", " 4452", "0", "10", "fail" , "above USL") /script
QAP/IQST fails. Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error. Review the results.html file for the failed test. If some some (or all) of “Composite phantom” measurements in the IQST results file, starting with “Lateral MTF at 2.0 lp/mm 20cmFOV”, provide “NODATA, missing measurement” error. The system is not properly detecting the composit phantom. Some or All of the composite phantom measurements indicate “NODATA, missing measurement” error. Review the results.html file for the failed test. It can be found in c:\Program files\ GE Medical Systems\IQST\ Scratch or c:\Program files\ GE Medical Systems\IQST\archive\xxxDatexxx. IApplies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.