INX100, Lost All Gantry axis's drive or NO movements
Symptom
INX100, Lost All Gantry axis's drive or NO movements The Gantry axis's will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor The Gantry axis' will not drive. The Innova Gantry is locked and will not drive the L-arm, Pivot, Arc, or Lift. Emergency backout works, L-arm clutch releases. Gantry Problem: reset the system to recover is displayed on the monitor
Error message
600501 Collimator power failure; wait automatic recover Collimator Power Failure 600501 Collimator power failure; wait automatic recover Innova: 600104 4F76 Collimator Can Heartbeat Error Innova Console: 4F76 Xray Abort Reposition coll blades. Patient Dose Mismatch.. on the SUIF Error Log: 600104 Collimator Control error Acquisition aborted; re-start. AR. Collimator CAN communication failure. 600104 AR XRBeamForm Collimator Control error Acquisition aborted; re-start Debug: XRBeamForm CAN Heart Beat Failure See LD for complete error. Innova Console: 4F76 Xray Abort Reposition coll blades. Patient Dose Mismatch.. on the SUIF Error Log: 600104 Collimator Control error Acquisition aborted; re-start. AR. Collimator CAN communication failure. 600104 AR XRBeamForm Collimator Control error Acquisition aborted; re-start Debug: XRBeamForm CAN Heart Beat Failure Check the power, Have found the 24v going to the footswitch to cause this issue by loading down the power supply.. error Code = 1000014, error Text = SID_SSD out of range, debug Text = SID out of range, recovery Class = IH, major Function /= XRImChainPos System impact: X-ray unavailable. Displayed message : "SID pb, use lift orange
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.