GE Healthcare · X-ray VascularInnovaAdvantx240001524000171610034240001110501601050161

INJECTION FAILED X-RAY ABORTED; during a run or run-off after the mask image.

Symptom

INNOVA: INJECTION FAILED X-RAY ABORTED; during a DSA aquisition or run-off after the mask image. The injector has failed to inject. The Innova aborts X-ray during a DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested. The Innova aborts X-ray during DSA aquisition or run-off after the mask image. The monitor dispay indicates Failed to start injector, Injector not injecting, Injector started at an unexpected moment, or unexpected Injection. The injector has failed to inject when requested.

Error message

error Code = 2400015, error Text = Injector started at an unexpected moment , debug Text += Unexpected injection, please release X-ray switches, recovery Class = AR, major Function /= XRPeriDevCtrl System impact: X-ray unavailable. Displayed message : "Injector start pb. Stop X-ray, reset system. If pb persists call service"

2400017 Failed to start injector followed by: 1610034 IP software error followed by: 2400011 Injector became unarmed during sequence 2400017 AR XRPeriDevCtrl Failed to start injector Debug: Injection failed, please restart followed by: 1610034 DO XRImProc IP software error Debug: Blacken requested by fibre channel command on Frontal Followed by: 2400011 WR XRPeriDevCtrl ALARM (! , 1.8) - Injector became unarmed during sequence Debug: [XRPeriDevCtrl::onInjectorDisArmed] Injector is not armed 2400017 Debug: Injection failed, please restart followed by: 1610034 Debug: Blacken requested by fibre channel command on Frontal Followed by: 2400011 Debug: [XRPeriDevCtrl::onInjectorDisArmed] Injector is not armed

2400017 Failed to start injector is logged in the error log 2400017 Failed to start injector AR XRPeriDevCtrl control Injector 1 0 Injection failed, please res

Applies to

Models
Innova, Advantx
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Component
Injector Injector Injector
Area
X-ray Vascular