Unable to Scan with TR bias Body open circuit Error after Mechanical Upgrade from 9X to HDX Performed by Mechanical Inst…

Unable to Scan with TR bias Body open circuit Error after Mechanical Upgrade from 9X to HDX Performed by Mechanical Installer.

Symptom

Unable to Scan with TR Driver Fault Detected Open Circuit. Source of Fault is Body TR Error after Mechanical Upgrade from 9X to HDX Performed by Mechanical Installer Upgrade from 9X to HDX. Unable to scan with "TR Driver Fault Detected - Open Circuit. Source of Fault is Body TR" which began immediately after mechanical upgrade performed by Mechanical Installer. See Long Description for the complete error message string logged when a scan is attempted. PQR 13093664 Mon Dec 18 15:57:19 2006 2252293 mrs3 NSP SCP:DCB 2915 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: BODY Scan: 50332/1 The Driver Module Has Detected a Fault. Details of the Fault can be found in other error messages.-> Mon Dec 18 15:57:19 2006 2252357 mrs3 NSP APS:aps_cf 243 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: BODY Scan: 50332/1 Driver Module error occurred. Mon Dec 18 15:57:20 2006 2224666 1 mrs3 psc PscMainControl.cc 1354 Exception Class: Unknown Function: Prescan: Host Autoprescan Auto Prescan failed, possible data acquisition error. Try again or use Manual Prescan. Mon Dec 18 15:57:20 2006 2252305 mrs3 NSP SCP:DCB 1289 Exception Class: Unknown Severity: Unknown Function: RF: RF Bias PSD: Spin Echo Coil: BODY Scan: 50332/1 TR Driver Fault Detected - Open Circuit. Source of Fault is Body TR. Value: 10 mA Limit: 2400 mA->

Error message

2252357 Driver Module error occurred. 2252357 1 lx-mr NSP APS:aps_fastta 135 Driver Module error occurred.

2252305 TR Driver Fault Detected Open Circuit Source of Fault is Body TR. Thu Aug 5 11:00:38 2004 Error: 2252305 Host: fmri3te Process: NSP File: SCP:DCB Line: 1197 TR Driver Fault Detected - Open Circuit. Source of Fault is Body TR. Value: 16 mA Limit: 2400 mA->

2252293 The Driver Module Has Detected a Fault. Wed Apr 21 20:00:24 2004 Error: 2252293 Host: lx-mr Process: NSP File: SCP:DCB Line: 1986 The Driver Module Has Detected a Fault.^A Details of the Fault can be found in other error messages.->

Applies to

Models
Excite
Product
Excite HDx Includes "Excite HDi" system. 14.0 Software only.
Software
14.0 For both Excite HDx and 3T Excite HDx systems.
Component
2319986 PLUG, 7/8 EIA RIGHT ANGLE
Area
MR

Full cause & step-by-step resolution