PSD Download Problems and Autoprescan Failures.

Symptom

PSD Download Problems and Autoprescan Failures See long description. PSD Download Problems and Autoprescan Failures The system is a 1.5T system with Excite. The FE just did an Excite I to Excite II upgrade running the 11.0_0332b software build (Excite II not Excite IIA). The FE downloaded all the M3 patches off the web and installed. After the upgrade was complete, the system fails to download any protocols with the Spin Echo PSD as well as some others. It will download FSE-XL, but autoprescan fails with signal too small when attempting to scan. Manual prescan shows flat line. If the FE puts in some approximate prescan values, the system will scan and produce an image but the image is split (nothing in the center and looks like wrap in from each side). See an example of this image on the OLC server in /data2_mr/ 423224MR1/image, e50973s4i11. This psd download problem appears to be similar to the problem which is addressed with patch #8, but the FE has already loaded on this patch. Additionally patch #8 shows up in the "getver" output. The following errors are seen in the log: Sun Dec 28 14:33:44 2003 Error: 2252553 Host: hopgemr1a Process: NSP File: AGP:RSP: wsinc Line: 0 PSD Programming Error: Parameter resolution is out of range. Value = 00000000, Lower Bound = 00000001, Upper Bound = 00007FFF PSD Parameters: pulsegen, 00000000, 00000000, 00000000, 00000000 Sun Dec 28 14:33:44 2003 Error: 2223825 Host: hopgemr1a Process: NSP File: PMH.cc Line: 843 Received a packet with opcode: 286, but wrong packet structure. Sun Dec 28 14:33:44 2003 Error: 2219712 Host: hopgemr1a Process: scn File: RxMgrDownload.m Line: 1184 The executable download of psd failed. PSD waveform generation failed. Sun Dec 28 14:33:44 2003 Error: 2218630 Host: hopgemr1a Process: scn File: RxManagerIF.m Line: 740 The download of a prescribed series failed. Internal status code is 2218501. Sun Dec 28 14:33:49 2003 Error: 2252728 Host: hopgemr1a Process: NSP File: AGP:pct_task.c Line: 946 PSD Programming Error: Wave generation watchdog has timed out. Sun Dec 28 14:33:49 2003 Error: 2248355 Host: hopgemr1a Process: NSP File: SCP:sct_mct_wavegen_status Line: 741 AGP to SCP State Error. SCT received a wavegen status 3 in a non-wavegen state 3 It may be necessary to perform a TPS reset. Sun Dec 28 13:41:28 2003 Error: 2227071 Host: hopgemr1a Process: NSP File: AGP:createinstr Line: 1 Pulse Width must be divisible by the hardware''s cycle rate times the pulse''s reso lution. pulse-> rf1as value->3200 cycle rate-> 2 resolution-> 0 Sun Dec 28 13:41:38 2003 Error: 2224725 Host: hopgemr1a Process: NSP File: APS:aps_frame_range_check Line: 10 Low signal detected. Please check the signal level for receiver 0 (or receiver 1 while using Manual Prescan). Sun Dec 28 13:41:38 2003 Error: 2224580 Host: hopgemr1a Process: NSP File: APS:aps_cf Line: 11 Auto Prescan failed. Signal was too small to process - use Manual Prescan. {sdc@hopgemr1a}[1] getver Hostname : hopgemr1a Build number for cclass is 11.0_M3_0332.b Build number for driverSupport is 11.0_M3_0332.b Build number for insite is 11.0_M3_0332.b Build number for install is 11.0_M3_0332.b Build number for MrpApps is 11.0_M3_0332.b Build number for mx_apps is 11.0_M3_0332.b Build number for mx_plat is 11.0_M3_0332.b Build number for mx_terra is 11.0_M3_0332.b Build number for OS is GEMS_Linux_1.7.6 Build number for patch_11.0_M3_01 is 11.0_M3_0332.b.PA Build number for patch_11.0_M3_02 is 11.0_M3_0332.b.PB Build number for patch_11.0_M3_03 is 11.0_M3_0332.b.PA Build number for patch_11.0_M3_04 is 11.0_M3_0332.b.PB Build number for patch_11.0_M3_06 is 11.0_M3_0332.b.PC Build number for patch_11.0_M3_07 is 11.0_M3_0332.b.PC Build number for patch_11.0_M3_08 is 11.0_M3_0332.b.PD Build number for pc is 11.0_M3_0332.b Build number for PostSdC is 11.0_M3_0332.b Build number for TERRA is IOS_M3_20030806_R292a MR Software release: 11.0_0332b

Error message

2227071 Pulse Width must be divisible by the hardware's cycle rate times the pulse's resolution Host: t19 Proc: NSP Error: 2227071 File: AGP:createinstr Line: 1 Pulse Width must be divisible by the hardware's cycle rate times the pulse's resolution. pulse-> rf1as value->3200 cycle rate-> 2 resolution-> 0 Host: b5 Proc: NSP Error: 2227071 File: AGP:createinstr Line: 1 Pulse Width must be divisible by the hardware's cycle rate times the pulse's resolution. pulse-> rf1cfl value->3200 cycle rate-> 2 resolution-> 0 Host: t19 Proc: NSP Error: 2227071 File: AGP:createinstr Line: 1 Pulse Width must be divisible by the hardware's cycle rate times the pulse's resolution. pulse-> rf1as value->3200 cycle rate-> 2 resolution-> 0 Host: b5 Proc: NSP Error: 2227071 File: AGP:createinstr Line: 1 Pulse Width must be divisible by the hardware's cycle rate times the pulse's resolution. pulse-> rf1cfl value->3200 cycle rate-> 2 resolution-> 0

2219712 The executable download of psd failed. PSD waveform generation failed. Error: 2219712 Host: hopgemr1a Process: scn File: RxMgrDownload.m Line: 1184 The executable download of psd failed. PSD waveform generation failed.

2218630 The download of a prescribe

Applies to

Models
Signa, Excite
Product
Signa LX Signa LX Product can be used with 8.x and 9.x systems.
Software
9.1 For Signa LX product only
Area
MR