Are the Medical Advances Large and Small Musculoskeletal Flex Array Coils, Vendor Part Numbers 543GE-64 & 544GE-64 Compa…
Are the Medical Advances Large and Small Musculoskeletal Flex Array Coils, Vendor Part Numbers 543GE-64 & 544GE-64 Compatible with 1.5T Excite HD?
Symptom
Are the Medical Advances Large and Small Musculoskeletal Flex Array Coils, Vendor Part Numbers 543GE-64 & 544GE-64 Compatible with 1.5T Excite HD? See Long Description On a Signa LX 9.1 to 1.5T Excite HD upgrade, the salesman promised the customer that the Medical Advances 543GE-64 and 544GE-64 "Long Bone" Large & Small Musculoskeletal Flex Array coils were compatible with 1.5T Excite HD. We don't sell these coils. On 9.1 software, the customer was using "USCTLMID" as the coil names for these coils and they worked fine. They are trying to use the same coil name now that the system has been upgraded to Excite HD and it doesn't work, they get coil ID errors. I can see these coils listed on the old 9x/10x cross reference spreadsheet in Excite HD Service Methods and the same coil names listed for these coils for 10x (Excite I) are present in the 1.5T 12x Excite HD Coil Config files. But these coils are not listed on the new Coils Compatibilty Matrix, nor elsewhere in Service Methods, no doubt because GE doesn't sell them, and I can find no coil ID cable to order from GE for these coils. These coils plug into the upper port so they must be Coil ID compatible. (If the coil's cable/connector is Coil ID compatible it will state this on connector). The 11x ISERV (coil ID was introduced with 11x software) gives a coil ID cable for a Medical Advances coil but that's for a knee/foot coil that we sell. There is no mention of these coils. The Excite HD upgrade includes "M1085PE RF Coil ID Cable Kit" but none of these cables seem to be for these coils. Are these coils compatible with 1.5T Excite HD, or not? If so how can we make them work with this system?
Applies to
- Models
- Excite, Signa
- Product
- Excite HD For 12.0 1.5T Systems only.
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.