Intermittent Omega V table longitudinal feedback pot
Symptom
Bolus run Aborted Failure ID ADXR KO: Bolus Chasing 1.0 Focal Spot Comment: Xrays Aborted after xx Images by error 50211 Bolus run Aborted Failure ID ADXR KO: Bolus Chasing 1.0 Focal Spot Comment: Xrays Aborted after xx Images by error 50211
Error message
50118 POS Table: Encoder, potentiometer failure; Debug: , HDW STATUS=0000 or HW 0001,USR STATUS=XXXX followed by 50211 POS Table: Motion control error during Bolus procedure. Both occur at the same time during a Bolus run. 50118 POS Table: Encoder, potentiometer failure; Debug: POS ERROR=4AC3, HDW STATUS=0000,USR STATUS=XXXX 50211 POS Table: Motion control error during Bolus procedure. Debug: [XRImChainPos::logPosError] Reporing the Motion Control error for GantryMotionControlError See LD for complete error. 50118 POS Table: Encoder, potentiometer failure; Debug: POS ERROR=4AC3,HDW STATUS=0000,USR STATUS=XXXX. HW and User status indicate Longitudinal Feedback pot problem. - Longitudinal Feedback pot problem 50118 POS Table: Encoder, potentiometer failure; Debug: , HDW STATUS=0001,USR STATUS=XXXX followed by 50211 POS Table: Motion control error during Bolus procedure. Both occur at the same time during a Bolus run. This indicates a problem with the Lateral Table Feedback Pot During a bolus run. Recalibrate the Table Lateral Potentiometer P403 Check the alignment and correct any mounting hardware issues 50211 POS Table: Motion control error during Bolus procedure. Debug: [XRImChainP
Applies to
- Models
- Innova, Advantx
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Software
- Bolus M3 DL release : DL_LBYBOLUSM3_6.17.050317; JEDI release : B6.30BFB. Ghost DL-3 : 18.7 Ghost DL-2 : 18.5 Ghost DL-5 : 20.4 DL : DL_LBYBOLUSM3_6.17.050317 DL Atlas Core : 3.1.R RTAC Atlas Core : 3.1.R IDC : 4.5.4 Calypso : 2.19 Calypso Uptime : BOLUS1.17.1 Positioner : 1.2.24B_IS6.5 Jedi : B6.30BFB
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.