Innova System boot failure Any defect that prevents from getting the first acquisition after the system reset.
Innova System boot failure
Symptom
Innova System boot failure Any defect that prevents from getting the first acquisition after the system reset. Customer needs to boot again to recover. When Innova system has a actor issue.
Error message
RTAC displays OCP Code 69H on Boot. 69h = Setup System Management Mode (SMM) area RTAC OCP Code of 69 on Boot. 69h = Setup System Management Mode (SMM) area The OCP code maybe seen as b9 (B9) 212011882 05/11/2010 13:02 GMT 2800059 IH XRSubSysMgrDL Failure of XRImProc during boot of the application Debug: component startup timeout 2800059 IH XRSubSysMgrDL Failure of XRImProc during boot of the application Debug: component startup timeout. May be followed by error codes 2800060, 2800061, 2800066, 2800006 2800059 IH XRSubSysMgrDL Failure of XRImProc during boot of the application Debug: component startup timeout May be followed by error codes 2800060, 2800061, 2800066, 2800006 2800060 IH XRSubSysMgrDL Failure of XRDataMgr during boot of the application Debug:component startup timeout 2800060 IH XRSubSysMgrDL Failure of XRDataMgr during boot of the application Debug: component startup timeout 2800061 IH XRSubSysMgrDL Failure of XRUserIfDL during boot of the application Debug: component startup timeout
Applies to
- Models
- Innova
- Product
- Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- RTAC in Innova RTAC in Innova RTAC in Innova Rtac's 128 meg memory stick 128MB Memory stick? Option 2 of the SN says to order FMI 12044 pn 5160221-3 if 128MB memory. cpu + memory from RTAC 1 chassis, part number 2271482 and swap memory the 128 meg memory stick into the old chassis. 128MB Memory stick? Option 2 of the SN says to order FMI 12044 pn 5160221-3 if 128MB memory cpu + memory from RTAC 1 chassis, part number 2271482 and swap memory the 128 meg memory stick into the old chassis.
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.