GE Healthcare · X-ray VascularInnova6004650125
Positioner TSSC or Smart handle/box.
Symptom
Positioner TSSC or Smart handle/box. A permanent validation or an error has been found on TSSC by PIB. Positioner TSSC. A permanent validation or an error has been found on TSSC by PIB. Positioner TSSC or Smart handle/box. A permanent validation or an error has been found on TSSC by PIB.
Error message
error Code = 60046, error Text = POS : SMART HANDLE CONTROL PROBLEM. CHECK IT OR CALL SERVICE, debug Text += pos-error=4B07, recovery Class = WR, major Function /= LC Gantry System impact: Permanent enable. Displayed message : "Smart handle problem. Please call service.". error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, HWStatus=00C5 error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry HW A6 = SH master - Permanent enable: TABLE DRIVING ENABLE (longitudinal & up/down) System impact: Permanent enable. Displayed message : None. error Code = 50125, hw-status=00A6, error Text = POS TSUI: SMB or SMH error, debug Text += pos-error=4ACA, hw-status=00A6, recovery Class = DO, major Function /= LC Gantry HW A6 = SH master - Permanent enable: TABLE DRIVING ENABLE (longitudinal & up/down) 50125 DO POS POS : TSUI: SMB OR SMH ERROR Debug: fct-status=0 hw-status=c5 pos-error=4aca usr-st
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.