GE Healthcare · X-ray VascularInnova1200105
Detector Temperature when first turn on will cause the DL not to boot because the Rtac will not boot if detector is to c…
Detector Temperature when first turn on will cause the DL not to boot because the Rtac will not boot if detector is to cold or issues with Conditioner.
Symptom
Detector Temperature when first turn on will cause the DL not to boot because the Rtac will not boot if detector is to cold or issues with Conditioner.
Error message
error Code = 1200105, error Text = Err_Detector Temperature, debug Text += Temperature out of range XX.XX degrees, recovery Class = WR, major Function /= XRImDet System impact: Message displayed to the customer. Displayed message : "Detector out of temperature range. If problem persists, call Service". See long description for further details. System impact: Message displayed to the customer. Displayed message : "Detector out of temperature range. If problem persists, call Service". Two cases can occur; either temperature above USL (Upper spec limit) or temperature below LSL (lower spec limit). Currently : USL = 35° C, LSL = 25° C. If measured detector temperature is outside this range, then an error 1200105 is generated.
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Detector conditioner power box Detector conditioner power box GESINOVAK1 Detector conditioner power box GESINOVAK1 from GE Supply and can be ordered via the iProcurement website .
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.