GE Healthcare · X-ray VascularInnova50104
Collision issues with tube and/or detector on power up.
Symptom
Collision Message on monitor, issues with tube and detector collision sensor on power up. Collision issues with tube and detector collision sensor on power up. The collision is gone after the tube or detector sensor is pushed.
Error message
error Code = 50104, HW=4 for the Detector Faceplate COLLISION error Text = POS : COLLISION DETECTION PROBLEM, debug Text += pos-error=4AB5, hw-status=0004, recovery Class /= WR, major Function /= VAS / POS System impact: Message displayed on monitors and BIP on TSSC every 30 seconds. Full gantry motion. Displayed message : "Collision detection failure, continue with care; Otherwise call Service" The Hardware code tells whether the problem is located on the Detector or on the Tube side: HW=4 for the Detector and HW=10 for the Tube Check the anti collision sensors on the Detector or tube. Touch the collision sensor margin on one side to re-balance the collision sensors. Touch the collision senso System impact: Message displayed on monitors and BIP on TSSC every 30 seconds. Full gantry motion. Displayed message : "Collision detection failure, continue with care; Otherwise call Service" The Hardware code tells whether the problem is located on the Detector or on the Tube side: HW=4 for the Detector Faceplate HW=8 is the Detector Bumper and HW=10 for the Tube. Check the anti collision sensors on the Detector. Touch the collision sensor margin on one side to re-balance the collision sens
Applies to
- Models
- Innova
- Product
- X Innova 4100 X Do not use---------4100 systems 4100 systems
- Software
- Bolus M4+ DL release : DL_LBYBOLUSM4_10.1.050805 Ghost DL-2 : NA Ghost DL-3 : 18.8 Ghost DL-5 : 20.6 DL : DL_LBYBOLUSM4_10.1.050805 DL Atlas Core : 3.1.R RTAC Atlas Core : 3.1.R IDC : 4.5.5 Calypso : 2.21 Calypso Uptime : BOLUS1.24 Positioner : 1.2.24B_IS6.6 Jedi : B6.30BFC
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.