The RRF data path Ex->Rx signal diagnostic sometimes incorrectly reports error message 2247357 with one or more of the f…
The RRF data path Ex->Rx signal diagnostic sometimes incorrectly reports error message 2247357 with one or more of the following text entries
Symptom
The RRF data path Ex->Rx signal diagnostic sometimes incorrectly reports error message 2247357 with one or more of the following text entries: See Long Description. Also see Resolution concept for the complete SMILe released December 1, 2006. See Resolution concept for the complete SMILe released December 1, 2006. Subject: RRF Data path Ex->Rx Signal Diagnostic May Incorrectly Report "Signal Leakage" Error 2247357. Effectivity: All 1.5T and 3.0T Signa HDx (14.0) MR systems. Problem: The RRF data path Ex->Rx signal diagnostic sometimes incorrectly reports error message 2247357 with one or more of the following text entries: "RRF Exciter to Receiver signal data path signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage." -or- "RRF Exciter Blanking data path signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage." -or- "RRF Receiver Blanking data path signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage."
Error message
2247357 RRF Exciter Blanking datapath signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage 2247357 RRF Receiver Blanking datapath signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage 2247357 RRF Exciter to Receiver signal datapath signal validation error. The RF Out and LO signals from the exciter to the receiver indicate signal leakage
Applies to
- Models
- Excite, Signa
- Product
- Excite HDx Includes "Excite HDi" system. 14.0 Software only.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.