Patient Comfort Level errors due to lack of "ipcm" option key
Symptom
Unable to Scan fMRI Functional MRI scans with Patient Comfort Trip errors See Long Description for a copy of the errors seen on the system when the Patient Comfort Trip errors occurred. Thu Sep 7 17:10:08 2006 2248650 TWD_MR3T NSP SCP:BoreTempSriHWO 1313 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Gradient Echo Coil: 8HRBRAIN Scan: 1597/7 The patient comfort level is warmer than normal. The patient may be uncomfortable. Further increases in temperature will inhibit scanning. Verify: 1. Patient fan is ON. 2. Room temperature is normal. 3. Air flow through the bore is unobstructed.-> Thu Sep 7 17:18:51 2006 2248652 TWD_MR3T NSP SCP:BoreTempSriHWO 1362 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Gradient Echo Coil: 8HRBRAIN Scan: 1597/9 Scan inhibited. Patient comfort sensor trip. To return to scanning, verify: 1. Patient fan is ON. 2. Scan room temperature is normal. 3. Air flow through the bore is unobstructed. 4. Gradient Cooling fan is normal. 5. BRM heat exchanger is normal.-> Thu Sep 7 17:22:58 2006 2224667 TWD_MR3T psc PscMainControl.cc 1363 Exception Class: Unknown Function: Prescan: Host Manual Prescan Manual Prescan failed, Patient comfort temperature sensor trip Thu Sep 7 17:23:02 2006 2224667 TWD_MR3T psc PscMainControl.cc 1363 Exception Class: Unknown Function: Prescan: Host Manual Prescan Manual Prescan failed, Patient comfort temperature sensor trip Thu Sep 7 17:23:24 2006 2224666 TWD_MR3T psc PscMainControl.cc 1354 Exception Class: Unknown Function: Prescan: Host Autoprescan Auto Prescan failed, Patient comfort temperature sensor trip Thu Sep 7 17:38:32 2006 2218650 TWD_MR3T scn ExamManager.c 542 Scn: No of Successful Scan = 4 , No of Failed Scan = 0 Thu Sep 7 17:44:31 2006 2248653 TWD_MR3T NSP SCP:BoreTempSriHWO 1333 Exception Class: Unknown Severity: Unknown Function: Software/Firmware/Config: N/A PSD: Gradient Echo Coil: 8HRBRAIN Scan: 1597/10 New scans can be initiated, but the patient comfort level is still warmer than normal.
Error message
2248652 Scan inhibited. Patient comfort sensor trip. See Long Description Mon Apr 5 07:37:02 2004 Error: 2248652 Host: lxmr3 Process: NSP File: SCP:BoreTempSriHWO Line: 999 Scan inhibited. Patient comfort sensor trip. To return to scanning, verify: 1. Patient fan is ON. 2. Scan room temperature is normal. 3. Air flow through the bore is unobstructed. 4. Gradient Cooling fan is normal. 5. BRM heat exchanger is normal. Extended Error: The bore temp that was measured by the SRI has reached the second trip level. Subsequent scans will not be allowed. If the bore temperature is not high, this could indicate a problem with the bore temperature sensor cable or the SRI. Please make sure that the bore temperature sensor cable is connected to the SRI and that it is positioned correctly in the bore. Possible cause(s): Bore Temp Sensor, SRI 2248653 New scans can be initiated, but the patient comfort level is still warmer than normal. 2248653 1 b4a NSP SCP:BoreTempSriHWO 1009 New scans can be initiated, but the patient comfort level is still warmer than normal. 2224667 Manual Prescan failed, Patient comfort temperature sensor trip 2224667 TWD_MR3T psc PscMainControl.cc 1363 Exception Class: U
Applies to
- Models
- Excite, Signa
- Product
- 3T Excite HDx 14.0 Software. The software that this solution is tied to is indicated by the Software concept below.
- Software
- 14.0 For both Excite HDx and 3T Excite HDx systems.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.