There is a beeping noise coming from the chiller unit
Symptom
There is a beeping noise coming from the chiller unit: There is a beeping noise coming from the cooling unit Coolix water treatment kit: (2286434 or 2286434-2) including: 1 pair of safety goggles, 1 pair of safety gloves, MSDS (Material Safety Data Sheet), 3 containers labeled “Empty”, 2 containers labeled “FLUSHING”, 3 containers labeled “TOPPING”, 10” Filter element (5144396) for Coolix 4000 (5115497). Note: Coolix 4000 chiller requires a quantity of two kits to complete the procedure. There is a beeping noise coming from the cooling unit or maybe and smells Coolix water treatment kit: (2286434 or 2286434-2) including: 1 pair of safety goggles, 1 pair of safety gloves, MSDS (Material Safety Data Sheet), 3 containers labeled “Empty”, 2 containers labeled “FLUSHING”, 3 containers labeled “TOPPING”, 10” Filter element (5144396) for Coolix 4000 (5115497). Note: Coolix 4000 chiller requires a quantity of two kits to complete the procedure.
Error message
error Code = 3602051 front, 3702051 Lat: Jedi: Chiller not working, debug Text += jedi-error=902h, tube cooling supply error, recovery Class = IH, major Function /= XRTechMgr 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed. System impact: X-ray unavailable. Displayed message : "Cooling Failure; Shut System down and call Service". Generally seen in system boot-up phasis or power issues. 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Innova Jedi Innova Jedi Innova Jedi
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.