Medicool/HX 10.0 P7 Vendor Manual tells how to troubleshoot for no pumping but not for no cooling.
Symptom
Medicool/HX 10.0 P7 Vendor Manual tells how to troubleshoot for no pumping but not for no cooling. In addition there is no way to tell if there is flow and how much. The troubleshooting in the vendor's manual tells how to troubleshoot for no pumping but not for no cooling. In addition there is no way to tell if there is flow and how much.The FE came in for scanning being inhibited due to "patient comfort level trip" error. The heat exchanger doesn't seem to exchange heat. He knows the pump is running but not if there is flow. The troubleshooting in the vendor's manual tells how to troubleshoot for no pumping but not for no cooling. In addition there is no way to tell if there is flow and how much.The FE came in for scanning being inhibited due to "patient comfort level trip" error. The heat exchanger doesn't seem to exchange heat. He knows the pump is running but not if there is flow.
Error message
2248652 Scan inhibited. Patient comfort sensor trip. See Long Description Mon Apr 5 07:37:02 2004 Error: 2248652 Host: lxmr3 Process: NSP File: SCP:BoreTempSriHWO Line: 999 Scan inhibited. Patient comfort sensor trip. To return to scanning, verify: 1. Patient fan is ON. 2. Scan room temperature is normal. 3. Air flow through the bore is unobstructed. 4. Gradient Cooling fan is normal. 5. BRM heat exchanger is normal. Extended Error: The bore temp that was measured by the SRI has reached the second trip level. Subsequent scans will not be allowed. If the bore temperature is not high, this could indicate a problem with the bore temperature sensor cable or the SRI. Please make sure that the bore temperature sensor cable is connected to the SRI and that it is positioned correctly in the bore. Possible cause(s): Bore Temp Sensor, SRI
Applies to
- Models
- Excite
- Product
- 3T Excite HD 12.0 software only
- Software
- 12.0 Excite HD and 3T Excite HD products only
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.