LVshim has high Z harmonics, images show a signal void (hole).
Symptom
LVshim has High Z Harmonics Images show a Signal Void hole See attached LVShim results notice Z harmonics and representative image of hole in phase images. @HDR 0 49 SITENAME = Columbia Presbyterian Eastside GRADMODE = C1 = No comment C2 = No comment @END @HDR 5 49 magnetSerNum = "D925" magnetType = "GE S-III" fieldStrength ="1.5T" room shielding (Yes/No) = "No" Magnishield (Yes/No) = "Yes" Shieldcooler type (0,1,2,3,4,5,6) = "lvshim.cfg" resistive shim power supply (0,1,2,3,4,5,6) = "0" external passive shim (Yes/No) = "No" passive shim drum (Yes,No) = "No" RFampType (ErbtecTube, ErbtecSolidState) = "10" spectroAmp (None, ENI) = "None" lineCondType (0,1,2) = "2" lineFreq (50,60) = "60" SRMode (120,77,50,20,17) = "120" ThisLineNotUsed = "" ThisLineNotUsed = "" ThisLineNotUsed = "" ThisLineNotUsed = "" @END @GRP 1 40 0 LARGE VOLUME SHIM CHECK GE S-III plane=6 bandwidth=200 fov=60 diameter=45, xmtfreq=63837068 Inhomogeneity(std)=110.72 hz, ( 1.734 ppm) spec=80 hz -----------Coil & Coefficients & Spec ------------------------- Z1: 20.13 [ 10] X: -3.40 [ 10] Z2X: 5.63 [ 50] Z2: -88.06 [ 60] Y: -22.08 [ 10] Z2Y: 32.04 [ 50] Z3: -304.70 [100] ZX: -14.04 [ 50] ZX2_ZY2: -217.38 [ 50] Z4: -58.99 [100] ZY: -299.80 [ 50] ZXY: 26.99 [ 50] Z5: 159.48 [100] X2_Y2: -52.47 [100] X3: -9.64 [100] Z6: 219.07 [200] XY: 1.66 [100] Y3: -13.51 [100] --------------------------------------------------------------- LV shim failed. @END @GRP 2 40 0 Coil Existing Delta New XGRAD -1.000 ---- -1.000 YGRAD -11.000 -2.000 -13.000 ZGRAD 18.000 2.000 20.000
Applies to
- Product
- Magnet S3. Software Version Concept should NOT be selected for Magnet Products Serial # (Dxxx) Field strength: 1.5 T LHe Boiloff Rate: Serial # (Dxxx) Field strength: 1.5 T LHe Boiloff Rate:< 0.2 liters/hr He Vessel Pressure:0.25 to 0.5 psig F1 Flow:0.4 to 0.6 SCFH F2 Flow:1.5 to 2.0 SCFH 1st Stage:40 to 58 Kelvin 2nd Stage:7 to 17 Kelvin Min. LHe Fill Level:30% (3 Dewar Fills) Min. LHe Fill Level:50% (2 Dewar Fills) Min. LHe Ramp Level:75% Min. LHe Shim Level:50% Helium Volume:1188 Liters (SIII) Burst Disk (integral gaskets) :2194545-4 Baffle Assy:46-318035G1 Shim Lead:46-260815G1 Shim Lead Large 5/8:46-318096G
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.