GE Healthcare · MR
What is the magnet bore length of a CX, LCC and G3 (LCC300 3T) magnet?
Symptom
What is the magnet bore length of a CX, LCC and G3 (LCC300 3T) magnet. CX magnet serial numbers start with a 'P' for 1.0T and a 'N' for 1.5T, LCC magnet serial numbers start with a 'Q' for 1.0T and a 'R' for 1.5T and G3 (LCC300 3T) magnet serial numbers start with a 'W'.
Applies to
- Product
- Magnet LCC 300. Software Version Concept should NOT be selected for Magnet Products Low Cryogen Consumption Serial number:Wxxx Field strength: 3.0 T He Vessel Pressure:>3 psig but <5 psig Shield Temp:< 55 Kelvin Coldhead Temp:> 3.8K but < 4.5K Recondenser Temp:> 4.2K but < 4.55K Delta Temp (Coldhead - Recondensor):> 0 but < 0.3K Min. LHe Fill Level: 60% Min. LHe Ramp Level: 100% Min. LHe Shim Level: 80% Helium Volume:1735 Liters Burst Disk:2349529 Burst Disk O-ring:46-281101P1 Baffle Assy: 2180818 Shim Lead Large 5/8:2173354 Magnet LCC. Software Version Concept should NOT be selected for Magnet Products Serial #: 1.5T (Rxxx) / 1.0T (Qxxx) He Vessel Pressure:>3 psig but <5 psig Shield Temp:< 55 K Coldhead Temp:> 3.8K but < 4.5K Recondenser Temp:> 4.2K but < 4.55K Delta Temp (Coldhead - Recondensor):> 0 but < 0.3K Min. LHe Fill Level: 50% Min. LHe Ramp Level: 90% Min. LHe Shim Level: 75% Helium Volume:1940 L (1.5T) Helium Volume:1970 L (1.0T) Burst Disk <":2319285 Burst Disk >":2350415 Burst Disk O-ring:46-281101P1 Baffle Assy 2180818 Low Cryogen Consumption Magnet CX. Software Version Concept should NOT be selected for Magnet Products Conquest Cx1.0T(Pxxx) / 1.5T(Nxxx) Magnets LHe Boiloff Rate: < 0.18 liters/hr He Vessel Pressure: 0.25 to 0.5 psig F1 Flow: 1.8 to 2.2 SCFH F2 Flow: 0.8 to 1.2 SCFH 1st Stage: 32 to 60 Kelvin 2nd Stage: 7 to 17 Kelvin Min. Operating LHe Level: 42% Min. LHe Ramp Level: 90% Min. LHe Shim Level: 75% Helium Volume: 1940 Liters (1.5) Helium Volume: 1970 Liters (1.0) Burst Disk <": 2319285 Burst Disk >": 2350415 Burst Disk O-ring: 46-281101P1 Baffle Assy: 2133618 Shim Lead Large 5/8: 2148084
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.