GE Healthcare · MRExcite22198031094564014222381720000235622200132223851
System fails to boot applications.
Symptom
System fails to boot Application Software. Can't ping anything in the MGD. Excite HD upgrade. First boot fails. Cant ping the Term Server or any of the boards in the MGD.
Error message
2219803 Could not register the object "theFreewheel" with Mr Mail. 1094564014 2 1 Tue Sep 7 13:33:34 2004 2219803 4 CHMMR scn SrxFreewheel.m 144 Could not register the object "theFreewheel" with Mr Mail. 2223817 TPS is Not Responding. Please Reset TPS Wed Apr 28 16:58:01 2004 Error: 2223817 Host: GEMS Process: NSP File: TardisReset.cc Line: 398 TPS is not responding. Please reset TPS. 200002356 dsserver died unexpectedly, no action being taken. Mon Nov 22 10:46:20 2004 Error: 200002356 Host: MRI1-OC0 Process: hostMonitor File: ssProcStop.c Line: 906 dsserver died unexpectedly, no action being taken. 2220013 Failed to Receive Coil Info Pkt from SCP Mon Nov 22 10:58:23 2004 Error: 2220013 Host: MRI1-OC0 Process: scn File: SrxCoilID.m Line: 124 Failed to Receive Coil Info Pkt from SCP 2223851 Reset TPS was not Successful. errno 11 -> 2223851 1 MROC_OC0 NSP TardisReset.cc 471 Reset TPS was not successful. errno : 11-> Note: The extended log below can be viewed from the Service Browser with the Service Key installed. Pull up the GE System log under the Error Logs tab. If there is an extended log available, the error number will be a hyperlink. Clicking on it will reveal the extended
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.0 Only for 1.5T Excite product. 12.0 is Excite HD and 14.0 is Excite HDx. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.