GE Healthcare · MRExcite225351816436
Array Processor Errors Due to Master AP Board.
Symptom
Array processor AP errors during scanning. Scans stop (abort) with an AP error logged. It appears that AP crashes are not related to heavy duty recon jobs or high data acquisition rates. A typical set of stress scans did not reproduce AP crashes. AP error file doesn't reveal any pattern either. Site currently has old style (Reflex-400A) boards. These boards were swapped for the newer Reflex-400B, but there was no change in symptoms. SPR MRIhc06568
Error message
2253518 The system did not find the right number of CPUs on the AP boards. Only 6 CPUs were found when there should be 8. This indicates that one of the AP boards may be partially defective.-> See Long Description 2253518 2 WFBIMRI diagCoord apBld.c 324 Diagnostic: Dual Board AP Mem Iteration: 1 of 1 Action: 1 Task ID: 0x3fa6948 Time: 16436 Object: APS Test Task The system did not find the right number of CPUs on the AP boards. Only 6 CPUs were found when there should be 8. This indicates that one of the AP boards may be partially defective.-> Extended Error : There should be 4 CPUs on each AP board. If there are two AP boards, this test can't tell which board is defective. Try reseating boards and verify each is in correct slot. If problem persists then replace single AP Board. If dual AP then configure to single AP and run diag again to isolate failure.
Applies to
- Models
- Excite
- Product
- Excite Includes Excite 1 and Excite 2, 10.0, 11.0 and 11.1 Software.
- Software
- 11.1 For product 1.5T Excite only. Note, 3T Excite goes with software G3, not 11.0 or 11.1.
- Component
- SecondOpinion MERCURY 910-07072 MINERVA II MASTER 2325947-12 See comments in resolution concept for second opinion requirements before ordering this part
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.