GE Healthcare · CTOptimaVCTBrightSpeed
Connect Pro Modality Work List will not update.
Symptom
Connect Pro Modality Work List will not update. Connect Pro Modality Work List will not update
Applies to
- Models
- Optima, VCT, BrightSpeed
- Product
- Optima CT660 10HW02.10.H40_P2_HS64_G_GMV 10HW33.8 H40_P2_HS64_G_GMV Optima CT660 Optima CT660 is a new design 64 slice scanner based on VCT and BrightSpeed technology. This is the first CT scanner as new Optima brand. check_config Product: Optima CT660 sw_version: 10HW02.10 or 10HW33.8 sw_hw_string: 10HW02.10.H40_P2_HS64_G_GMV or 10HW33.8_SP3-0-1.H40_P2_HS64_G_GMV host_id: 1943170864 tube_type: 19 gantry_type: GANTRY_HP_40 No. of processors: 8 Processor speed: 2527 memory: 24576 hinv CPU: GenuineIntel Intel(R) Xeon(R) CPU E5540 @ 2.53GHz 8 2527 MHz x86_64 Processors Secondary cache: 8192 KB FPU: GenuineIntel Intel(R) Xeon(R) CPU E5540 @ 2.53GHz Floating Point Main memory size: 24576 Mbytes SCSI controller 10: Version usb-storage Disk drive: unit 00 on SCSI controller 10, Lun 00 SCSI controller 9: Version usb-storage Disk drive: unit 00 on SCSI controller 9, Lun 00 SCSI controller 0: Version mptsas Disk drive: unit 00 on SCSI controller 0, Lun 00 Disk drive: unit 01 on SCSI controller 0, Lun 00 16550A UART serial port: 000003F8 Graphics board: VGA Ethernet interface configured: eth3 Ethernet interface configured: eth0 Ethernet interface configured: eth1 Dual Channel Display Table weight limit: GT1700V Table The Lite table ( currently for Japan Market) 450 Pounds (205 kg) Table: The normal table is 500 Pounds (227 kg) Table: X-Ray Tube Modified Performix D3187T Green Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 10HW33.8 - used on RIO OC 10HW33.8 Used on RIO Optima CT660 ClassC 5384724-3 ClassM 5384725-3 Software Collector – 10HW33.8 5389067-3 SP1 part of FMI 26824 or 26825 SP2 part of FMI 26826 ( SP1 included on CD) SP3 is in forward production. FMI slated for late 2011 or early 2012. SP1 and SP2 are required •Introduces 32 slice configuration, upgradable to 64 slice. •Overlapped Recon option. •Introduce Dose Check feature for U.S. market. •Supports new hardware due to EOL.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required