GE Healthcare · CTLightSpeedVCT230015036230017152244563230017156122040230017160
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Collimator Cal fails the Mylar window check
Error message
Error: 230015036 /usr/g/cal_db/tracking/coll_cal/2x0625/small_spot/ collimator_cal does not exist See Long Description for Details Wed Feb 20 16:26:57 2008 Error: 230015036 Host: bay44 Process: scanUtilsRx File: cal_db_utils.c Line: 1235 /usr/g/cal_db/tracking/coll_cal/2x0625/small_spot/collimator_cal does not exist Error: 230017152 ACCS: Could not complete pre-process(ACCS_PREP_MWCHECK). Wed Feb 20 16:27:36 2008 Error: 230017152 Host: bay44 Process: accs File aircal_spectral.c Line: 1148 ACCS: Could not complete pre-process(ACCS_PREP_MWCHECK). Error: 244563 Scan Seq Id: 0 File /usr/g/service/state/cnvBrdId.cfg does not exist or can not be opened See Long Description for Details Wed Feb 20 16:26:57 2008 Error: 230015036 Host: bay44 Process: scanUtilsRx File: cal_db_utils.c Line: 1235 /usr/g/cal_db/tracking/coll_cal/2x0625/small_spot/collimator_cal does not exist Error: 230017156 ACCS Prep: Error of pre-processing was returned Wed Feb 20 16:27:35 2008 Error: 230017156 Host: bay44 Process: accs File: accs_single_prep_mgr.c Line: 340 ACCS Prep: Error of pre-processing was returned Number of rows: 64, Max Number of views: 992, Size of 1 view: 122040 Input View Data : start view: 9,
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required