LightSpeed 1.X - GRE

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 183952 Gantry (Axial) LOOP CONTACTOR Error. OVERSPEED condition - Could NOT CLOSE Gantry (Axial) Loop Contactor. Axial Gantry Command/Status:0x129e00. HW Error: A RESET of the STC controller is required and try again. See Long Description for Details. Error: 183952 Gantry (Axial) LOOP CONTACTOR Error. Thu Jan 26 09:01:27 2006 Error: 183952 Suite: CT01 Host: STC Process: Axial File: ax error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Loop Contactor Interlocks Scan: 4756/3/0 Type: None/Unknown Exception Level: Pri/Most Severe Time: 09:01:24:635 Log Series: 392 Gantry (Axial) LOOP CONTACTOR Error. OVERSPEED condition - Could NOT CLOSE Gantry (Axial) Loop Contactor. Axial Gantry Command/Status:0x129e00. HW Error: A RESET of the STC controller is required and try again.

Error: 183921 Axial conditions at FAULT: See Long Description for complete error Mon Oct 17 08:26:48 2005 Error: 183921 Suite: SMCT Host: STC Process: Axial File: ax_error.c Method: No Method Line: 1114 Function: AXIAL CONTROL : Axial Servo Control Loop Scan: 28848/2/1 Type: Helical Exception Level: Pri/Most Severe Time: 08:26:47:775 Log Series: 141 Axial conditions at FAULT: velocity_fb = 266

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-264806G2 AXIAL CONTROL BOARD ALLOWING .8 SEC See long description for details Part #: 46-264806G2 Part Type: GP REPAIRABLES Part Weight: 1.81 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: AXIAL CONTROL BOARD ALLOWING .8 SEC FRU: Yes Status: Orderable Comments: OBSOLETE PART case 6763061 This part has been identified as obsolete and no short-term solution has been identified FE must identify and order a higher or lower level spare part as required Contact your support engineer on-line engineer or Parts ID team should you require support 212012173 05-23-07 FLS - FE ASSIT: MS6588 05/22/98 46-264806G2 = AXIAL BD FOR CTI& QXI SYSTEMS WITH 0.8 SEC SCANNING. THIS BOARD HAS THE PALS FOR 0.8 SECOND ROTATION. THE T3202KD = .8 SEC AXIAL BD. THE T3202BD =1.0 SEC AXIAL BD. THE ONLY DIFFERENCE BETWEEN THE T3202KD AND T3202BD ARE TWO PALS. THE T3202BD CAN BE UPGRADED TO THE T3202KD BY CHANGING PALS U211 AND U101. DO YOU STILL WANT TO ORDER THIS PART?
Area
CT