GE Healthcare · MRSignaExcite226307522630785063322544152263101
UART communication error Due to UPM NB Amp IF Board.
Symptom
UART Communication Errors 2263078 UART Communication Error. A software transmit overflow occurred on a UART link 2263075 UART Communication Error. A software receive overflow occurred on a UART link
Error message
2263075 UART Communication Error A software receive overflow occurred on a UART link 2263075 NSP SCP:../uartLib.c 440 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Unknown Coil: Unknown Scan: -1/-1 UART Communication Error A software receive overflow occurred on a UART link. Source: RF NB Amp Interface UART: Debug UART 2263078 A software transmit overflow occurred on a UART link Mon Dec 11 12:47:09 2006 Error: 2263078 Host: MR1 Process: NSP File: SCP:../uartLib.c Line: 343 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: Spin Echo Coil: BODY Scan: 50633/1 UART Communication Error A software transmit overflow occurred on a UART link. Source: RF NB Amp Interface UART: Debug UART 2254415 Attention: RF Amplifier in service, not product mode 2254415 NSP SCP:../rf_debug.c 443 Exception Class: Unknown Severity: Unknown Function: RF: RF Transmit PSD: Unknown Coil: Unknown Scan: -1/-1 Attention: RF Amplifier in service, not product mode. The RF Amplifiers are being controlled via the serial terminal. Reset the RF Amplifier Interface or Reset TPS to return control to the system. 2263101 CAN Communication Error A
Applies to
- Models
- Signa, Excite
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2391146 UPM NB AMP IF BOARD, also known as ASC RF Interface Board.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.