Discovery CT590 / Optima CT580 / RT

Symptom

Pop-up appears upon boot-up: An unrecognized X-Ray tube has been installed on the system.

Error message

Error: 244643 Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. See Long Description for complete error Thu Dec 21 15:35:37 2006 Error: 244643 Host: nsuhct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 326 Tube identity advisory: An unrecognized X-Ray tube has been installed on the system. GE Medical Systems cannot assure that the system performance will conform to specifications.

Error: 244644 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report. See LD for more details Sat Jun 17 10:21:57 2006 Error: 244644 Host: jfkct2 Process: fwmgr File: tubeApprovalPopupMgr.cxx Line: 329 Tube identity advisory: Advisory messages will be posted to the operator about an unrecognized tube during system startup, during tube warm-up, during Fast Calibration, and in the dose report.

Applies to

Models
Discovery, Optima, VCT, BrightSpeed
Product
Discovery CT590 / Optima CT580 / RT Discovery CT590 RT (16 slice CT for Oncology) Optima CT580 RT (8 slice CT for Oncology) Optima CT580 W (16 slice Radiology CT for Bariatric and Interventional, etc.) Freedom RT16 see long description for details Product Name: Discovery and Optima RT Discovery CT590 RT (16 slice CT for Oncology) Optima CT580 RT (8 slice CT for Oncology) Optima CT580 W (16 slice Radiology CT for Bariatric and Interventional, etc.) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo List of Supported Console Types TIO (True-In-One Console) List of softwares the product can run 09BW35.11+SP1.7 10BW06.5+SP1.5 FAQ's GT 1700 Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy GT 650 High Capacity Table 650 lbs. Tube type - D3194T D3193T(green) Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. RT Freedom Service Introduction - SN130902B
Area
CT

Full cause & step-by-step resolution