The HFA Control Board was tripping the over temperature fault when a FIESTA-C scan was running. "Y-Axis Overtemperature…
The HFA Control Board was tripping the over temperature fault when a FIESTA-C scan was running. "Y-Axis Overtemperature Fault" Scanning FIESTA-C Protocol, Scan Aborts.
Symptom
"Y-Axis Overtemperature Fault" Scanning FIESTA-C Protocol, Scan Aborts Unable to complete a FIESTA-C scan. Sequence>TE=minimum, Flip Angle=75, Band Width=62.5, Freq Matrix=384, Phase Matrix=256, NEX=2 FOV=20, SliceThickness=1, Locs per Slab=32 The scan aborted with error code 2244579 "The GP is reporting a Y Axis OverTemperature Fault. System will wait 5 minutes before attempting recovery.->. Changed Rx to FIESTA by copying FIESTA-C sequence (except for NEX so as to maintain the same scan time) and had no problem. The problem only occurs with FIESTA-C Unable to complete a FIESTA-C scan. Sequence>TE=minimum, Flip Angle=75, Band Width=62.5, Freq Matrix=384, Phase Matrix=256, NEX=2 FOV=20, SliceThickness=1, Locs per Slab=32 The scan aborted with error code 2244579 "The GP is reporting a Y Axis OverTemperature Fault. System will wait 5 minutes before attempting recovery.->. Changed Rx to FIESTA by copying FIESTA-C sequence (except for NEX so as to maintain the same scan time) and had no problem. The problem only occurs with FIESTA-C
Error message
2244579 The GP is reporting a %x Axis OverTemperature Fault. System will wait 5 minutes before attempting recovery 2244579 The GP is reporting a %x Axis OverTemperature Fault. System will wait 5 minutes before attempting recovery.->
Applies to
- Models
- Signa, Excite
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2396050-2 HFA CONTROL BOARD ASSEMBLY
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.