Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.
Symptom
Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76
Error message
1610034 DO XRImProc IP software error followed by 1600018 AR XRImProc Front: An asynchronous error has been detected by the IP, abort req. See long description for full pattern. 1610034 DO XRImProc IP software error followed by 1600018 AR XRImProc Front: An asynchronous error has been detected by the IP, abort req. Abort sequence on a record acquisition. Note 1 : EM_IP_SW_ERROR error is related to error code 1610034. Note 2 : May also get from time to time errors related to IP processor such as 1610028, 1600019 1600019 WR XRImProc Front: An asynchronous error has been detected by the IP, warning generated. Debug: Rootcause: see the EM_IP_SW_ERROR error 1610028 DO XRImProc Front: Frontal Processing Board Error. Debug: DriverVortex::_checkErrIT() -> VTX_FAULT_INTERRUPT_AP(0x00000001) - VTX_FAULT_REGISTER_AP_1(0x20000000) - VTX_IMEM1_AP
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.