GE Healthcare · X-ray VascularInnova36020513702051
After pressing the off button on the vicm, the system did not shut down properly.
Symptom
After pressing the off button on the vcim, the system did not shut down properly. Looking for The DL monitor displays " It is safe to turn off your computer"
Error message
error Code = 3602051 front, 3702051 Lat: Jedi: Chiller not working, debug Text += jedi-error=902h, tube cooling supply error, recovery Class = IH, major Function /= XRTechMgr 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed. System impact: X-ray unavailable. Displayed message : "Cooling Failure; Shut System down and call Service". Generally seen in system boot-up phasis or power issues. 3602051 Front,3702051 Lat: Jedi: Chiller not working IH XRTechMgr acquisition Lat Chiller not working 0 1 JEDI Error Code: 0902H tube cooling supply error Data Related to Error: 0 Tube 1 70C: Set, Tube 40C: Set, Rotor Thermal Error: OK, Inverter thermal Error: OK, Tank thermal Error: OK, Door Status: Closed
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova 2000 Innova 2000 systems Innova 2000 systems
- Component
- Coolix XR Tube Chiller Coolix XR Tube Chiller Coolix XR Tube Chiller
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.