Grainy or Low SNR Due to Improper Coil Selection Used For Given Image FOV
Symptom
MRCustomerCall Image Artifact Library Image Quality This issue has been written to assist in supporting remote Customer calls for Image Quality issues. See long description for more details. This issue has been written to assist in supporting remote Customer calls for Image Quality issues. Take a look at the attached image gallery and see if the issue matches one of the common problems. Once you identify the name of the IQ issue, you can go to the resolution concept titled by that name to get information on that type of image quality problem. Additionally, it is good to ask the following general questions about the issue to help understand. Artifact Characterization/History of Occurrence Questions •How long has artifact been occurring? •Frequency of occurrence, often or intermittent? •Check Chronology history any images previously pulled? •Patient Specific or Multiple Patients? •Coil Specific or Multiple Coils? Have they reseated the coil and re scanned?
Error message
2224725 Low signal detected. Please check the signal level for receiver X (or receiver X while using Manual Prescan) See Long Description Error: 2224725 Host: hopgemr1a Process: NSP File: APS:aps_frame_range_check Line: 10 Low signal detected. Please check the signal level for receiver X (or receiver X while using Manual Prescan).
Applies to
- Models
- Signa, Excite
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- Running grafidy3, and find there are spikes on the waveforms in the manual prescan display, both windows.
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- Fails to Scan with TORSO Coil.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- AE title has changed on destination host.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.