GE Healthcare · X-ray VascularInnova410011410012
UPS, Exam interruption risk if power is lost.
Symptom
UPS, Exam interruption risk if power is lost. UPS failure. Call Service 410011 ups 4567 UPS, Exam interruption risk if power is lost. UPS failure. Call Service 410011 ups 4567. Command Load on Mains; The UPS (UPS system) transferred the output from Inverter to Mains by opening K7, followed by turn on of the SSM.
Error message
410011 Fluoro UPS problem: Load on Inverter (OFF) Battery loading followed by 410012 UPS error. Check UPS error log. 410011: Root Cause: Fluoro UPS problem This error is logging a problem detected on the UPS. Recommended Action: Make sure that the battery is well charged. If not the case, wait for the battery to charge. Verify the UPS for internal errors. To do so, open a browser on the DL and check the UPS internal errorlog. Verify the connection between the UPS and the On/Off board. 410012: Root Cause: Fluoro UPS problem This error is logging a problem detected on the UPS. Recommended Action: Make sure that the battery is well charged. If not the case, wait for the battery to charge. Verify the UPS for internal errors. To do so, open a browser on the DL and check the UPS internal errorlog. Verify the connection between the UPS and the On/Off board.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- SG-20 KVA UPS SG-20 KVA UPS Seelong. SG-20 KVA UPS OPM_SGS_USM_10K_40K_0US_V010.pdf 5380482 UL PDB Phase Control Relay LS1
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.