KAXV Migration Test Issue

Symptom

KAXV Migration Test Issue KAXV, This issue is to be used to test the migration from SW5.5 to Consona 8.0

Error message

TUBE spits. 3602040, error Text = Jedi: Spit or kV instability error, debug Text += jedi-error=316h, Spit Max error, data related to error <> 8, recovery Class = AR, major Function /= XRTechMgr TUBE Spits. System impact: X-ray unavailable. Displayed message : "Xray aborted - Restart Xray; if problem persists, call Service".

error Code = 810028, error Text = System is not calibrated for 3D : never calibrated or corrupted calibration files., debug Text += ERROR: the 3D calibration file is not valid, recovery Class = IH, major Function /=XRDataMgr System impact: Exam failure. Displayed message : "System is not calibrated for 3D. Perform 3D calibration or Call Service.".

INX100: 1050166 BUMP SENSOR PROBLEM, debug Text = - Cyclical Error, recovery Class = WR, major Function /= GantryAxis System impact: Message displayed on monitors and BIP on TSSC every 30 seconds. Full gantry motion. Aborts Bolus acquisition. Displayed message : "Collision detection failure, continue with care; Otherwise call Service" 1050166 BUMP SENSOR PROBLE M, debug Text = - Cyclical Error, recovery Class = WR, major Function /= GantryAxis System impact: Message displayed on monitors and BIP on TSSC every 30 seco

Applies to

Models
Innova, Advantx
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Software
$INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144. Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production $INX1PRO or IQ+, Harmony M4 HP2 or Harmony HP1 FMI12144 Note: HP2 software release is equivalent to HP1 software release + gantry vibration fix for Harmony M4 forward production. $ IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1 IQ+ or PRO table, ELEGANCE_IS2, DL_ELEGANCE_3.2.1
Component
5172115 Image tube power supply for BIPLANE Advantx. 5172115 Image tube power supply for BIPLANE Advantx. Coolix water treatment kit THE NEW Coolant kits are now 2286434-3 100000155 06/14/2011 11:45 GMT 1 pair of safety goggles, 1 pair of safety gloves, MSDS (Material Safety Data Sheet), 3 containers labeled “Empty”, 2 containers labeled “FLUSHING”, 3 containers labeled “TOPPING”, 10” Filter element (5144396) for Coolix 4000 (5115497). Note: Coolix 4000 chiller requires a quantity of two kits to complete the procedure. THE NEW Coolant kits are now 2286434-3 including: 100000155 06/14/2011 11:45 GMT 1 pair of safety goggles, 1 pair of safety gloves, MSDS (Material Safety Data Sheet), 3 containers labeled “Empty”, 2 containers labeled “FLUSHING”, 3 containers labeled “TOPPING”, 10” Filter element (5144396) for Coolix 4000 (5115497). Note: Coolix 4000 chiller requires a quantity of two kits to complete the procedure. Fiber optics test kit number 5122510 - order through tools depot Reference the fiber testing results XLS or the appropriate ASM or RP. (Kit must be ordered through tools depot). Reference the fiber testing results XLS or the appropriate ASM or RP. (Kit must be ordered through tools depot). INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2 INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2. Follow job card DR0182 for FRU replacement. Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-9-2EN Rev 1 and is provided for your reference from the Innova 2100-IQ, 3100/3100-IQ, 4100/4100-IQ DVD documentation. To view the most recent appropriate and detailed documentation, click to go to MY WORKSHOP INX100: Jedi AC/DC 3ph Mid Power assy - FRU ref 2323150-2. Follow job card DR0182 for FRU replacement. Always use the most appropriate documentation for your system. The following was taken from Direction 5160408-9-2EN Rev 1 and is provided for your reference from the Innova 2100-IQ, 3100/3100-IQ, 4100/4100-IQ DVD documentation. To view the most recent appropriate and detailed documentation, click to go to MY WORKSHOP
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.