GE Healthcare · MRExcite226485522275562266418
Unable to scan with DCERD Temperature Error 2266418 due to Intermittent Pushed Pin
Symptom
Unable to scan with DCERD Temperature Error 2266418 See Long Description HDe system posts error 2266418, along with a string of errors that seem to point to a major problem in the System Cabinet. The errors mention SRF, WARP CPU, and B0 correction problems.
Error message
2264855 RF SUBSYSTEM NOT RESPONDING The DCERD chassis is not communicating to the MGD chassis. See Long Description 2264855 RF Transmit RF SUBSYSTEM NOT RESPONDING The DCERD chassis is not communicating to the MGD chassis. Try TPS Reset. If this problem repeats, call service. Scanning will not be possible. Verify that the DCERD chassis is powered on.-> 2227556 *** Reset/Download TPS was not successful. *** 2227556 sdm sdm_main.c 320 *** Reset/Download TPS was not successful. *** 2266418 DCERD Temp. Sensor detects an over temperature 2266418 NSP SCP:CabMonHWO 569 Exception Class: Unknown Severity: Unknown Function: Power/Support Systems: Cabinet Monitor PSD: Spin Echo Coil: GPFLEX Scan: 6114/6 Cabinet Monitor:DCERD Temp. Sensor detects an over temperature. The system turns power off the DCERD. Please contact your Service Representative and check it with them.-> Extended Error: ERROR: EM_CABMON_DCERD2_TEMP_OUT Cabinet Monitor:DCERD Temp. Sensor detects an over temperature. The system turns power off the DCERD. Please contact your Service Representative and check it with them. Possible cause(s): Cabinet Monitor
Applies to
- Models
- Excite
- Product
- Excite HDe. For Hino HDe 14.0 and HDe 15.0 Software Systems only
- Software
- HDe 15.0 For Hino Excite HDe 15.0 systems only.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- TPS/MGD fails to download or reset. mgd_term windows fail to mount file system.
- The Carriage Fails to Advance to Latch to the Table and to Retract When it is Raised, Undocked or Lowered.
- Unable to Load Applications Software during restoreinfo Due to Corrupt saveinfo Disk.
- CWA ID100315. Auto and Manual Prescan Fails.
- Ghosted or Smeared Head Images Using Head Coil due to Head TR Assembly.
- A Copper Coolant Line or Pipe Internal to the MCS Cabinet Chiller Burst due to Water Remaining in Unit Freezing During Shipment.