The CAN Link is Reporting Hard or Intermittent CAN Link Failures due to ASC chassis.Replace UPM-ASC Chassis Assembly Exc…
The CAN Link is Reporting Hard or Intermittent CAN Link Failures due to ASC chassis.Replace UPM-ASC Chassis Assembly Excite HD wqr.3.0T Signa HDxT.2363041 UPM/ASC chassis
Symptom
The CAN Link is Reporting Hard or Intermittent CAN Link Failures. Any device on the CAN Link may suddenly start reporting hard or intermittent CAN Link failures and CAN Link communications may be interrupted. Replacing the suspect part will not fix the problem.
Error message
2254031 The slave RRF-DIF board was not detected on the system CAN bus 2254031The slave RRF-DIF board was not detected on the system CAN bus. Extended Error: This message indicates that the slave RRF-DIF board in the Remote RFChassis may not have the CAN bus connected. There are CAN in and outconnections on the RRF-DIF board, ensure that the cable is connected to both.For more information run the CAN Link Diagnostic. 2252243 Network Management Failure detected on the CAN network. A CAN node stopped responding to messages. Failing Node is Master Gradient.-> See Long Description Fri Feb 8 10:42:15 2008 Error: 2252243 Host: SLGIRMA01 Process: NSP File: SCP:CanLinkHWO Line: 993 Exception Class: Unknown Severity: Unknown Function: Peripherals: Communications PSD: t1memp Coil: 8HRBRAIN Scan: 7544/7 Network Management Failure detected on the CAN network. A CAN node stopped responding to messages. Failing Node is Master Gradient.-> Extended Error : The CAN node indicated stopped responding to watchdog messages from the SCP. Check that the node has power and that the CAN cable is connected. This could also happen if a node was manually powered off. 2252239 Startup Timeout was detected on
Applies to
- Models
- Signa, Excite
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2363041 UPM/ASC chassis 2363041 UPM/ASC chassis
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.