Can not store the Start and End position during a Bolus Chase.
Symptom
INX100: Can not store the Start and End position during a Bolus Chase. Acquisition is not allowed. Can not store the Start and end position during a Bolus Chase. During the setup of a bolus chase, after pushing the Store button for the start position, the light does not turn on to allow the end position to be stored. The message "Move table to available range to store position" is logged in the system logs to indicate the end button was pushed. Acquisition is not allowed and "Store Start/End position to start the acquisition" is displayed if the Record button is selected. Can not store the Start and end position during a Bolus Chase. During the setup of a bolus chase, after pushing the Store button for the start position, the light does not turn on to allow the end position to be stored. The message "Move table to available range to store position" is logged in the system logs to indicate the end button was pushed. Acquisition is not allowed and "Store Start/End position to start the acquisition" is displayed if the Record button is selected.
Error message
INX100: XRSvcMgr.log indicates 200058 - Store Start/End position to start the acquisition XRSvcMgr.log indicates 200058 - Store Start/End position to start the acquisition. displayError, error message displayed = Move table to available range to store position is displayed on the In room monitor. XRSvcMgr.log indicates 200058 - Store Start/End position to start the acquisition. displayError, error message displayed = "Move table to available range to store position" is displayed on the In room monitor.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Positioner Gantry Positioner Gantry Positioner Gantry
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.