Angulation not displayed when reviewing on AW Innova sequences
Symptom
INX1PRO-IQ+: Table height displays > 99 at boot, even if rotation is set off afterwards When system is booted with table top rotation off centered, then on IRD Table height displays > 99, preventing MED apps (QCA/QCA) to be started. This display remains, even if rotation is set off afterwards, only cleared by System Reset. When System is booted with table top rotation off centered, then on IRD Table height displays > 99, and Table Tilt displays > 99 (even with Omega Table), preventing MED apps (QCA/QCA) to be started. The usual "workaround" to set rotation off ( back to center ) does not work. The only way to clear the issue is System Reset or Shutdown.
INX1PRO-IQ+: Unable to start Medical Application package on DL INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA QCA (Quantitative Coronary Analysis), LVA QVA (Quantitative Ventricular Analysis) INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA <=> QCA (Quantitative Coronary Analysis), LVA <=> QVA (Quantitative Ventricular Analysis) when starting Stenosis Analysis on ITU.
INX1PRO-IQ+: Angulation not displayed when reviewing on AW Innova sequences INX1PRO-IQ+: Angulation not displayed when reviewing Innova sequences on AW. When reviewing the sequence on DL, the angulation is displayed during the review on the DL image monitor. The sequence can be pushed without problem on AW workstation. But when reviewing the sequence on AW, angulation is not displayed during review on AW image monitor.
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
- Component
- Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.