GE Healthcare · X-ray VascularInnova
PDS VASC_PDS_ concepts hag
Symptom
PDS VASC_PDS_ concepts hag PDS VASC_PDS_ concepts
Error message
H-page Warning Error message, No acquisition attempted before next reset requested. DO NOT close H-page case with this error selected. Review the system log and select correct error or abandon case. H-page Warning Error, No acquisition attempted before next reset requested, reset on same patient ID or BOOTFAILURE_WARNING or Hard down with no reboot after Reset. DO NOT close H-page case with this error selected. Review the system log and select correct error or abandon case. H-page Warning Error message, No acquisition attempted before next reset requested, fast resume after Reset, reset on same patient ID, BOOT FAILURE_WARNING or Hard down with no reboot after Reset. DO NOT close H-page case with this error selected. Review the system log and select correct error or abandon case . H-page Abort Error message, system abort or reset. DO NOT close H-page case with this error selected. Review the system log and select correct error or abandon case. . H-page Abort Error message, System abort or reset with same patient ID, no successful acquisition since last boot; possible Boot Failure causing the customer to reboot, reset on same patient ID or hard down with no reboot after Reset. DO N
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.