Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova2800029

Unable to start Medical Application package on DL popup message when starting Stenosis Analysis on ITU.

Symptom

INX1PRO-IQ+: Unable to start Medical Application package on DL INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA QCA (Quantitative Coronary Analysis), LVA QVA (Quantitative Ventricular Analysis) INX1PRO-IQ+: Unable to start Medical Application package on DL. Customer selects a sequence and reviews it on DL. Then he cannot start either SA (Stenosis Analysis) or LVA (Left Ventricular Analysis) applications. Note : SA <=> QCA (Quantitative Coronary Analysis), LVA <=> QVA (Quantitative Ventricular Analysis) when starting Stenosis Analysis on ITU.

Error message

2800029 WR XRSubSysMgrDLDatabase inconsistency failure 2800029 WR XRSubSysMgrDLDatabase inconsistency failure. Debug: No MedApp can be made on this sequence because field (0x0019, 0x8F, 'GEMS_DL_IMG_01') contains NO_QCA value -> acquisition issue Error logged in errorlog file when attempting to start Medical Application. Note : you may have following errors after a record acquisition:

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues