182183 Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor.

Symptom

Xray aborted, stopped- Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor. This is any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). Xray aborted - Restart Xray; if problem persists, call Service is displayed on the Innova Image monitor This is caused by any defect in a vascular system that prevents it from making X-rays for at least one request (Fluoro or Record). Sometimes, a reset system may be needed to recover X-rays (case IH error follows abort error). errors: 600104 IN2K: Error 4F76

Error message

3602041 Jedi: kV problem detected AR XRTechMgr acquisition JEDI_KV_detected_not_OK 1 0 JEDI Error Code: 0319H kV unbalanced detected Data Related to Error: 0 Tube 1 70C: OK Tube 40C: Set Rotor Thermal Error: OK Inverter thermal Error: OK Tank thermal Error: OK Door Status: Closed Phase: HV_ON XRPAtlasLogger.cpp 156 3602041: Root Cause: JEDI: KV detected not OK Related to a hardware defect or a regulation problem. Root cause Probability PPC kV control Board Medium HV tank Medium Flat cable Low HV cables Low Recommended Action: Check the flat cable between PPC kvctl board and HV tank. If damaged, replace it. Run No load HV diagnostic from SUIF/Jedi Diagnostics (Refer to "Jedi Diag #20002 No Load kV Diagnostics" jobcard in the system TSG): remove HV cables and fill HV receptacles with oil. If test passes, check HV cables. If test fails, replace PPC kV control board. If error persists, replace HV tank. The FRU Isolation Perimeter is shown in a Green frame in the figure below:

Applies to

Models
Innova
Product
Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
Component
Ulysses MX160 X-Ray Tube Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload) Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload)
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.