Image Quality Degraded; Tube inspection requested displayed during fluoro or Record, may hear loud popping noise coming…
Image Quality Degraded; Tube inspection requested displayed during fluoro or Record, may hear loud popping noise coming from tube
Symptom
JEDI: Tube Spit or kV instability, steady state error Related JEDI: Tube Spit or kV instability, steady state error Related. X-rays acquisition can be aborted if too many tube spits are occuring. JEDI: Spit or kV instability, steady state error Related. X-rays acquisition can be aborted if too many tube spits are occuring.
Image Quality Degraded; Tube inspection requested displayed during fluoro or Record, may hear loud popping noise coming from tube Image Quality Degraded; Tube inspection Requested displayed during fluoro or Record, may hear loud popping noise coming from tube Image Quality Degraded. Tube inspection Requested displayed during fluoro or Record , may hear loud popping noise coming from tube.
Error message
3602016 Degraded image quality, tube inspection requested WR XRTechMgr acquisition Component(s)_Tube 1 0 [XRTechMgr::notifyGeneratorFinalExposureParameters] numberOfTubeSpits=7 above the maxNumberOfTubeSpits=2 after 2 frames XRTechMgr.cpp 1958 3602016 "Degraded image quality, tube inspection requested" WR XRTechMgr acquisition Component(s)_Tube 1 0 [XRTechMgr::notifyGeneratorFinalExposureParameters] numberOfTubeSpits=7 above the maxNumberOfTubeSpits=2 after 2 frames XRTechMgr.cpp 1958
Applies to
- Models
- Innova
- Product
- Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Component
- Ulysses MX160 X-Ray Tube Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload) Ulysses MX160 X-Ray Tube Part number 2216500 (new) or D2802A (reload)
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.