GE Healthcare · X-ray VascularInnova3000007310000750000202800066
Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.
Symptom
Xray not available; Reset system to recover, Call Service is displayed in the Image monitor.
Error message
3000007 (FRT) or 3100007 (LAT) Error in Communication Facility XRSubSysMgr Followed by 5000020 and 2800066 IH Failure during boot process on Start up of the system. 3000007 (FRT) or 3100007 (LAT) Error in Communication Facility XRSubSysMgr Followed by 5000020 and 2800066 IH Failure during boot process on Start up of the system. Case Frontal communication error 3000007 AR Front: Error in Communication Facility XRSubSysMgr control Frt _Component(s)_ETHERNET_Communication [XRSubsysMgrRTAC::uponCommunicationError] XRSubsysMgrRTACFront::COMM_ERROR_7:: ERROR: PublishEvent on Other Router Followed by 5000020 DO Error in Communication Infrastructure SubSysMgr control Component(s)_ETHERNET_Communication XRImChainPosFront::COMM_ERROR_7:: ERROR: PublishEvent on Other Router And System boot fails with the error message 2800066 IH Failure during boot process XRSubSysMgrDL Degraded Boot Software_Problem XRDataMgrFrt component startup timeout. Case lateral communication error Same pattern as frontal one with following changes: Error 3100007 and Lat instead of Frt.
Applies to
- Models
- Innova
- Product
- Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System
- Software
- SPAD M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1 SPAD (Biplane) M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1 - MCB fix is related to frontal LC vibrations fix. SPAD (biplane) M4 TR2 MCB fix BIP_6.4.0, DL_SPAD_4.25.1. MCB fix is related to frontal LC vibrations fix.
- Area
- X-ray Vascular
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare X-ray Vascular issues
- The Worklist does not refresh on the system when performing a query.
- Innova System boot failure
- INX1X; Message Limit switch engaged; LP4 Lateral Detector lift will not move after going to max SID using the Emergency Backout button on the lift cover because the lift hit maximum (Max) SID limit sw…
- Firewall is broadcasting DHCP addresses
- Cooling Failure; Shut System down and call Service is displayed on the Innova Image monitor
- No gantry motion is reported by the customer.