Pular para o conteúdo principal
GE Healthcare · X-ray VascularInnova5011850211

ID180457 The longitudinal table top movement starts and stops while driving.

Symptom

The longitudinal table top movement starts and stops while driving. While driving the table in the longitudinal direction from the TSUI, the movement starts and stops.

Error message

50118 POS Table: Encoder, potentiometer failure; Debug: , HDW STATUS=0000 or HW 0001,USR STATUS=XXXX followed by 50211 POS Table: Motion control error during Bolus procedure. Both occur at the same time during a Bolus run. 50118 POS Table: Encoder, potentiometer failure; Debug: POS ERROR=4AC3, HDW STATUS=0000,USR STATUS=XXXX 50211 POS Table: Motion control error during Bolus procedure. Debug: [XRImChainPos::logPosError] Reporing the Motion Control error for GantryMotionControlError See LD for complete error. 50118 POS Table: Encoder, potentiometer failure; Debug: POS ERROR=4AC3,HDW STATUS=0000,USR STATUS=XXXX. HW and User status indicate Longitudinal Feedback pot problem. - Longitudinal Feedback pot problem 50118 POS Table: Encoder, potentiometer failure; Debug: , HDW STATUS=0001,USR STATUS=XXXX followed by 50211 POS Table: Motion control error during Bolus procedure. Both occur at the same time during a Bolus run. This indicates a problem with the Lateral Table Feedback Pot During a bolus run. Recalibrate the Table Lateral Potentiometer P403 Check the alignment and correct any mounting hardware issues 50211 POS Table: Motion control error during Bolus procedure. Debug: [XRImChainP

Applies to

Models
Innova
Product
Innova X1 X1 Biplane Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X1 X1 Bi-plane Innova 2121 or 3131 Bi-plane System Innova X100 Monoplane Innova X100 Monoplane from product name Innova 2100, 3100 and 4100 Innova X100 Monoplane Innova 2100, 3100 and 4100 Innova 2000 Innova 2000 systems Innova 2000 systems
Component
Omega V Table Omega V Table Omega V Table Innova 2100–IQ Case Innova 2100–IQ System can be supplied with an OMEGA IV Compact patient table, an OMEGA V long patient table, which includes a table side control with Contour Filter, or a InnovaIQ patient Table. Innova 3100/3100-IQ and 4100/4100-IQ Case Innova 3100/4100 Systems can be supplied with an OMEGA V Long patient table or InnovaIQ patient Table, which includes a table side control with Contour Filter. Illustration 2-1: Omega patient table (with TSSC)
Area
X-ray Vascular

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare X-ray Vascular issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare X-ray Vascular issues